How to improve your plants efficiency: Plant Betterment for Valves and Control Systems

Operating power plants efficiently is very important in the economics of power generation. Optimizing efficiency requires that all power plant systems function at peak performance over long-term operation.

Control valves are the final control elements in any system process. Therefore, their performance affects plant efficiency directly. This is especially true of severe service control valves, which are a small fraction of all the control valves in a power plant. Recent experience suggests a potential for gain in plant performance of 2 to 5%, based on improving the performance of control valves.

Examples of Megawatt savings and gains are:

  • Taiwan Power Company, Kuosheng I & II: 24 Megawatt gain was realized by replacing the main feedpump (MFP) recirculation valves
  • Central Nuclear Vandellos: Main feedwater control valves (MFCV) retrofitted with DRAG® technology solved the control problems: a bonus while solving the control problems was a 2 Megawatt savings
  • Commonwealth Edison , Quad Cities I and II: 6 Megawatt gain was achieved by retrofitting the heater drain valves
  • Salem Harbor Station, formerly New England Power: A new DRAG feedwater control valve combined functions of the main flow control valve as well as the startup valve. The smoothness of control reduced the time for startup by two hours
  • Tata Electric Company: A new feedwater control valve replaced the old conventional valve to provide smooth control, reducing the time for startup by two hours and eliminating the potential for trips due to feedwater control problems during startup

The Critical Role of Severe Service Valves

Eliminating problems in severe service valves offers one of the quickest and most effective means of improving plant efficiency. Of the hundreds of control valves in any power plant, severe service valves are those subjected to tough operating conditions either all or part of the time. Although few in number, they pose challenges to maintenance and operation.

Main steam leaking from atmospheric vent valve

In most cases, problems are caused by the misapplication of general service valves in severe service duty. In severe operating conditions, such misapplications affect overall efficiency to a greater degree, compared to the entire valve population.

 

How Severe Service Valve Problems Affect Plant Efficiency

Even though key parameters are monitored in power stations, severe service control valves traditionally have not been included in the efficiency analysis. This may have been due to a combination of factors – their treatment only as “necessary evils” in control, poor recognition of their contribution to plant efficiency and, perhaps, a lack of systematic methods for quantifying their effect on efficiency. The net result is that control valves tend to be the most under-rated and ignored elements in power plant operation.

The visible effects of control valve problems most often include loss in production capacity, occasional plant trips, frequent maintenance, and safety concerns. In addition, valve problems can trigger other invisible costs, such as penalty in heat rate/high operating cost, longer startup time, and lower Unit availability.

The issue of control valve performance goes even further. Occasional transients that cause operating conditions beyond the normal range may cause collateral damage to other expensive plant equipment, such as turbines, heaters, and boiler tubes. Low flexibility in operation, e.g. part-load operation, or sliding pressure mode in fossil power plants may not be possible even when it is desirable.

Examples of Severe Service Control Valves

Examples of severe service control valve applications in the main power-generating loop in nuclear power plants include main feedpump (MFP) minimum flow control, feedwater control, turbine bypass, atmospheric dump and emergency heater drains. In addition, there are many other severe service valve applications in various systems in nuclear plants, such as residual heat removal (RHR), high pressure core injection (HPCI), service water, high pressure injection (HPI), reactor coolant system (RCS) and chemical volume control system(CVCS).

Examples of severe service control valve applications in fossil power plants include the boiler feedpump (BFP) minimum flow control, feedwater control, spraywater control, auxiliary steam control, heater drains, turbine bypass and startup valves.

In such severe service applications, typical symptoms observed include:

  • Premature trim and body erosion due to lack of control of fluid velocity along the flow path
  • Poor shutoff capability, resulting in further damage to the sealing surfaces
  • Poor process control
  • Poor dynamic response

All of these problems can be eliminated by applying solutions which address the root cause directly.

Areas for Performance Gain with Optimum Control Valve Performance

There are four major areas for preventing losses using optimum control valve performance.

  1. Direct energy loss due to leakage: CV leakage has a direct impact on the heat rate and efficiency of the Unit. In applications such as the turbine bypass valves, emergency heater drain valves, main steam drain valves, and boiler feedpump recirculation valves (shut tight during normal operation), any leakage means loss of energy from the system.
  2.  Efficiency penalty due to leakage: In applications such as the attemperator spray valves in fossil-fired power plants, the leakage flow causes the steam temperature to drop. As a result, the boiler must be fired harder to raise the steam temperature to the set value. This causes a penalty in heat rate and loss in efficiency.
  3.  Reduction of energy loss in valves: The basic mechanism in valves for process control requires pressure drop. This pressure drop results in loss of available work, directly and indirectly. Any reduction of this loss means more work is available from the system. By managing the valve pressure drop from a system perspective, the efficiency of the plant can be improved at full-load and part-load conditions. Often, this optimization results in reduced stresses on other expensive equipment in the power plant, as well.
  4. Availability: Improved availability means higher production, i.e. more MW-hours. Good control valve performance can increase availability in more ways than one, such as shorter startup and shutdown time, and elimination of load limitations attributable to control valve non-performance.

Estimating Potential for Improvement

Quantifying the potential for improvement is an important step in any system to realize the full benefits. Generally, the efficiency losses due to individual valve applications are small, but together they add up to a significant value. Every power plant is unique in some ways and therefore, the methods for estimation of these losses must be applied judiciously. More importantly, these methods must inspire confidence in the resulting estimates based on reasonable assumptions and experience.

Case – MFP recirculation valve

One of the simplest calculations to perform is the estimation of MWe loss due to leakage caused by damage to the sealing surface. The following case involved a main feedpump (MFP) recirculation valve in a pressurized water reactor plant. This case demonstrates the method itself, and imparts a sense of the magnitude of such a loss.

The cage from the MFP recirculation valve after one cycle of operation is shown below. Measurements of the damage to the sealing surface indicate its total cross-sectional area to be 0.087 sq. in.

Damaged trim from main feedpump (MFP) recirculation valve showing areas of damage on the sealing surface. The depth and width of individual damage locations were measured to arrive at an equivalent leakage area.

The corresponding flow capacity (CV) through the damaged area, i.e., the leakage rate = (0.087 sq.in.) (31) = 2.7

For upstream flow conditions of 1150 psig and 431ºF, and condenser pressure downstream,

Leakage flow:

Q = (Cv)(DP/G)1/2 = 83.1 gpm, where G is the specific gravity.

This translates to approximately 35,100 lbs./hour of leakage. The loss of energy from the cycle due to leakage is easily determined. The enthalpy upstream is known from process conditions to be 409.7 Btu/lbm; the enthalpy of the condensate is 69Btu/lbm.

Therefore, the estimated energy loss is = (35,100 lbs/hour)(409.7–69) = 3.9MW-thermal.

This is loss per valve. At 33% overall efficiency, the loss in electrical power is 1.3MWe. Since there are 2 valves per Unit, the total loss is 2.6 MWe for the Unit.

This estimate is in line with the experience at PSE&G, Hope Creek, which reported a gain in 2 MWe by replacing the leaky MFP recirculation valves!

Typical valve trim damage due to cavitation/erosion/vibration in severe service applications.

If the typical damage is known from previous maintenance history, it can be used directly in the same manner.

In some circumstances, a judgment call based on past results in similar experiences may be the best possible input. Needless to say, the quality ofthe assumptions is reflected in theresults.

Experience in the Industry

The correct application of technologies in severe service control valves has yielded significant benefits. For example, a survey of once-through supercritical fossil plants showed that plants with “velocity control” DRAG® technology in their severe service valves for the start-up system (SUS) experienced negligible losses, whereas plants with conventional valves suffered noticeable loss in generation capacity, plus the heat rate penalty. In the nuclear industry, the application of DRAG technology in the main feedwater control (MFCV) and turbine bypass (TB) valve applications has removed many long-standing reliability problems, resulting in higher production.

CCI’s approach to increasing power plants’ efficiency

CCI takes a diverse approach in identifying potential improvements in a plant’s operation. It has evolved from experience in solving severe service valve problems, which requires substantial knowledge and understanding of the systems.

CCI has appointed a dedicated group to study power plants for efficiency improvement. The group is comprised of qualified professionals who have many years of proven experience in the CV and power generation industry.

The process in a CCI study includes:

  • On-site visit
  • Review and evaluation of the plant cycle
  • Discussions with plant personnel in the efficiency, operations and maintenance departments
  • Study of available data regarding plant’s history
  • Identification of specific control valve problems and their impact on plant efficiency

The CCI Solution involves:

  • Offering generic solutions, specifications and budgetary estimates.
  • Outlining strategies for implementing solutions.
  • Providing technical support during implementation of solutions.
  • Lending technical support for verification of projected performance gain.

Finally, performance improvement in a power plant can be achieved through many different approaches. However, experience to date makes a compelling case for putting the economic focus on control valves in order to achieve performance gains.

To quote the Chief Engineer of a large utility in his address to plant managers, “…it is not a question whether or not you can afford DRAG® technology, rather a simple fact that you cannot afford not to have it in severe service valves.

Published in SOLUTIONS Winter 1999

 

 

Article 1
Solutions to increase MWE
Article 2
Why SteamJet is the preferred solution
Article 3
The importance of ISA design criteria
Article 4
MHI chooses CCI as their global supplier for turbine bypass systems
   
Article 5
CCI selected to provide units for new nuclear power plant
Home   |   Subscribe   |   About us   |   Ask the Valve Doctor   |   Contact Us

Copyright © 2006. CCI - Control Components Inc. All Rights Reserved.